Respiratory test for detecting Helicobacter pylori

AMA Med
The ammonium breath test is a non-invasive and rapid method for detecting Helicobacter pylori infection, a bacterium associated with gastritis and gastric ulcers. The procedure involves measuring the concentration of ammonium in the patient's breath before and after administration of a C12 urea solution, a process in which Helicobacter pylori produces urea, converting urea into ammonium and carbon dioxide. The test is recommended for children and pregnant women, as it does not require the ingestion of radioactive isotopes. Results are available in about 15 minutes, allowing the effectiveness of therapy to eradicate the infection to be assessed.
Product Code: HELIC ABT Do you need help? 0732846883 / 0725129997
  • Description
  • Reviews (0)

The ammonium breath test is a simple and non-invasive method for detecting Helicobacter Pylori infection. It was created to eliminate pain and discomfort for patients during testing.

 

Helicobacter Pylori produces large amounts of urease, which breaks down urea into ammonium (NH4+). The breath test uses the kinetic recording of the ammonium concentration in the patient's breath before and after the administration of C12 urea. The value of the ammonium level is expressed in the color change of the composition in the test tube.

 

NON-INVASIVE AND PAINLESS

The testing procedure is non-invasive and painless. The test can be done before and after Helicobacter Pylori eradication therapy.

FAST

Testing takes only 15 minutes

SURE

Testing does not require ingestion of radioactive isotopes. The test is recommended for children and pregnant women.

EXACTLY

Clinically proven accuracy.

 

Test procedure:

 

Ask the patient to insert the tube into the oral cavity. Start the suction pump. Inhale the exhaled air for 6 minutes.
The patient should drink 0.5 g of urea dissolved in 50 ml of water. After ingesting the urea solution, the patient should rinse his mouth with water.
Turn the tube over and connect it to the hose. Ask the patient to insert the tube into the oral cavity. Start the suction pump. Inhale the exhaled air for 6 minutes.
Interpret the result. HP+ or HP- according to the instructions for use.

 

For more information about the breath test, you can visit the website www.hptest.ro.